Skip to Content

South Campus Equipment

Aria #1 Cell Sorter

Optics/Configurations: 3-laser, 9-color

Laser: 405

Filter 450/50BP
Alexa Fluor405, DAPI, Marina Blue, Pacific Blue, eFluor450, Sytox Blue, Calcien Blue, BV421

Filter 530/30 BP
Alexa Fluor430, AmCyan, CFP, Live Dead fixable Aqua, BV510

Laser: 488 

Filter 530/30 BP
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 576/26 BP
PE, DS Red

Filter 610/20 BP
PE-Texas Red

Filter 695/40 BP
PE-Cy5, PerCP, PerCP-Cy5, PerCP-Cy5-5, PI, 7AAD

Filter 780/60 BP
PE-Cy7

Laser: 633 

Filter 660/20 BP
APC, Alexa Fluor647, Sytox Red

Filter 780/60 BP
Alexa Fluor700, APC-CY7, APC-H7

Software Version: BD FACSDiva 6.1.3

Sample Tube: 12mmX75mm polystyrene tube

Sample Collection

15ml tubes (up to two populations)
12mmX75mm tubes (up to four populations)
1.5ml microcentrifuge tubes (up to four populations)
24,96,384 well plates

Nozzle/pressure: 70um 70psi  (default), 100um (by request; call flow staff for more information)

Aria #2 Cell Sorter

Optics/Configurations: 2-laser, 7-color

Laser: 488 

Filter 530/30 BP
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 576/26 BP
PE, DS Red

Filter 610/20 BP
PE-Texas Red

Filter 695/40 BP
PE-Cy5, PerCP, PerCP-Cy5, PerCP-Cy5-5, PI, 7AAD

Filter 780/60 BP
PE-Cy7

Laser: 640 

Filter 660/20 BP
APC, Alexa Fluor647, Sytox Red

Filter 780/60 BP
Alexa Fluor700, APC-CY7, APC-H7

Software Version: BD FACSDiva 6.1.3

Sample Tube: 12mmX75mm polystyrene tube

Sample Collection

15ml tubes (up to two populations)
12mmX75mm tubes (up to four populations)
1.5ml microcentrifuge tubes (up to four populations)

Nozzle/pressure: 70um 70psi  (default), 100um (by request; call flow staff for more information)

Influx Cell Sorter

Optics/Configurations: 5-laser, 14-color

Laser: UV355 

Filter 460/50 BP
Hoechst Blue

Filter 670/30 BP
Hoechst Red

Laser: 405 

Filter 460/50BP
Alexa Fluor405, DAPI, Marina Blue, Pacific Blue, eFluor450, Sytox Blue, Calcien Blue, BV421

Filter 520/35 BP
Alexa Fluor430, AmCyan, CFP, Live Dead fixable Aqua, BV510

Laser: 488 

Filter 530/40 BP
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 670/30 BP
PerCP, PI, 7AAD

Filter 695/40 BP
PerCP-Cy5, PerCP-Cy5-5

Laser: 561 

Filter 585/29 BP
PE, DS Red

Filter 610/20 BP
PE-Texas Red, Alexa Fluor610, mCherry, mKate, tdTomato

Filter 670/30 BP
PE-Cy5

Filter 750LP
PE-Cy7

Laser: 640 

Filter 670/30 BP
APC, Alexa Fluor647, Sytox Red

Filter 720/40 BP
Alexa Fluor700

Filter 750 LP
APC-CY7, APC-H7

Software Version: BD Sortware 1.2

Sample Tube: 12mmX75mm polypropylene tube

Sample Collection: 

15ml tubes (up to two populations)
12mmX75mm tubes (up to four populations)
50ml tube (up to two populations in combination with 1.5ml tube)
1.5ml microcentrifuge tubes (up to four populations)
24,96,384 well plates

Nozzle/pressure: 100um 24 psi (default), 70um 52psi (by request; call flow staff for more information)

Jazz Cell Sorter*

Optics/Configurations: 2-laser, 6-color

Laser: 488 

Filter 530/40 BP
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 576/26 BP
PE, DS Red

Filter 629/40 BP
PerCP, PerCP-Cy5, PerCP-Cy5-5, PI, 7AAD

Filter 750 LP
PE-Cy7

Laser: 640 

Filter 670/30 BP
APC, Alexa Fluor647, Sytox Red

Filter 750 LP
APC-CY7, APC-H7

Software Version: BD Sortware 1.2

Sample Tube: 5ml polypropylene tube

Sample Collection: 

15ml tubes (up to two populations)
12mmX75mm tubes (up to four populations)
50ml tube (up to two populations in combination with 1.5ml tube)
1.5ml microcentrifuge tubes (up to four populations)
24,96,384 well plates

Nozzle/pressure: 100um 24psi (fixed)
*class II biosafety cabinet

Sony Synergy HAPS1 & 2 Cell Sorter*

Optics/Configurations: 4-laser, 14-color

Laser: 405 

Filter 460/50BP
Alexa Fluor405, DAPI, Marina Blue, Pacific Blue, eFluor450, Sytox Blue, Calcien Blue, BV421

Filter 520/35 BP
Alexa Fluor430, AmCyan, CFP, Live Dead fixable Aqua, BV510

Laser: 488 

Filter 530/40 BP
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 670/30 BP
PerCP, PI, 7AAD

Filter 695/40 BP
PerCP-Cy5-5

Laser: 561 

Filter 585/29 BP
PE

Filter 610/20 BP
PE-Texas Red, Alexa Fluor610, mCherry, mKate, tdTomato

Filter 670/30 BP
PE-Cy5

Filter 750LP
PE-Cy7

Laser: 640 

Filter 670/30 BP
APC, Alexa Fluor647, Sytox Red

Filter 720/40 BP
Alexa Fluor700

Filter 750 LP
APC-CY7, APC-H7

Software Version: Winlist 7.1

Sample Collection: 

15ml tubes (up to two populations)
12mmX75mm tubes (up to four populations)
1.5ml microcentrifuge tubes (up to four populations)
24,96,384 well plates

Nozzle/pressure: 100um 24 psi (default), 70um 52psi (by request; call flow staff for more information)
*class II biosafety cabinet

LSRFortessa Cell Analyzer

Optics/Configurations: 4-laser, 13-color

Laser: 405 

Filter 450/50BP
Alexa Fluor405, DAPI, Marina Blue, Pacific Blue, eFluor450, Sytox Blue, Calcien Blue, BV421

Filter 525/50 BP
Alexa Fluor430, AmCyan, CFP, Live Dead fixable Aqua, BV510

Filter 605/12 BP
Qdot605, Pacific Orange, BV605

Laser: 488 

Filter 530/30 BP
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 710/50 BP
PerCP, PerCP-Cy5, PerCP-Cy5-5, PI, 7AAD

Laser: 561 

Filter 585/15 BP
PE, DS Red

Filter 610/20 BP
PE-Texas Red, Alexa Fluor610, mCherry, mKate, tdTomato

Filter 660/20 BP
PE-Cy5

Filter 710/50
PE-Cy5.5

Filter 780/60 P
PE-Cy7

Laser: 640 

Filter 670/14 BP
APC, Alexa Fluor647, Sytox Red

Filter 730/45 BP
Alexa Fluor700

Filter 780/60 BP
APC-CY7, APC-H7

Software Version: BD FACSDiva 6.1.3

Sample Acquisition: 12mmX75mm polystyrene tubes

Canto II Cell Analyzer

Optics/Configurations: 3-laser, 8-color

Laser: 405 

Filter 450/50BP
Alexa Fluor405, DAPI, Marina Blue, Pacific Blue, eFluor450, Sytox Blue, Calcien Blue, BV421

Filter 510/50 BP
Alexa Fluor430, AmCyan, CFP, Live Dead fixable Aqua, BV510

Laser: 488 

Filter 530/30 BP
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 585/42 BP
PE

Filter 670 LP
PE-Cy5, PerCP, PerCP-Cy5-5, PI, 7AAD

Filter 780/60 BP
PE-Cy7

Laser: 633 

Filter 660/20 BP
APC, Alexa Fluor647, Sytox Red

Filter 685LP
Alexa Fluor700

Filter 780/60 BP
APC-CY7, APC-H7

Software Version: BD FACSDiva 6.1.3

Sample Acquisition: 12mmX75mm polystyrene tubes
HTS plate reader (96 well plates)

Calibur Cell Analyzer

Optics/Configurations: 2-laser, 4-color

Laser: 488 

Filter 515-545
Alexa Fluor488, FITC, GFP, Sytox Green, Calcien Green

Filter 564-606
PE, DS Red

Filter 670-820
PerCP, PerCP-Cy5, PerCP-Cy5-5, PI, 7AAD

Laser: 635

Filter 653-669
APC, Alexa Fluor647, Sytox Red

Software Version: Cell Quest

Sample Acquisition: 12mmX75mm polystyrene tubes

Sony EC800Cell Analyzer

Optics/Configurations: 4-laser, 6-color
Co-linear cell analyzer: flexible color options

Software Version: EC800

Sample Acquisition: 12mmX75mm polystyrene tubes
96 well plate reader
Autosampler for 2x75 mm, PCR, or eppendorf tubes, and more than 10 plate formats
great for routine assays

BD Pathway 435 II Cell Imager

Optics/Configurations: 4-channel automated spinning disk

Excitation Filter 377/50 BP Emission Filter 435 LP
DAPI, Hoechst

Excitation Filter 482/35 BP Emission Filter 536/40
Alexa488, Calcein, Cell Tracker Green, Cy2, FITC, GFP,
Mito Tracker Green

Excitation Filter 543/22 BP Emission Filter 593/40
Alexa546, Alexa555, Alexa594, Cell Tracker Orange, Cell Tracker Red, Cy3, Mito Tracker Red, Propidium Iodide,
Texas Red, TRITC

Excitation Filter 543/22 BP Emission Filter 593/40
Alexa647, BODIPY, Cy5

Emission Filter 593/40
Transmitted Light

Software Version: BD Autovision 1.6

Sample Acquisition: 96,384 well plates (black photo bottom)


Back to Equipment main


© 2013 The University of Texas MD Anderson Cancer Center